XU Min1,DONG Chao-wen1,OUYANG Wei2,WANG Guo-zhong3 (1.School of Information Engineering,Nanchang University,Nanchang 330031,China;2.Nanchang Engineering and Research Institute of Nonferrous Metals,Nanchang 330002,China;3.Utility Plants of Dexing Copper M
Abstract:The lightning protection status of Dexing Copper Mine in recent yeas is introduced.Taking the 35 kV Xiashan substation of Dexing Copper Mine as an example,ATP-EMTP software is used to simulate the lightning invasion wave in the substation,and some corresp
徐敏; 董超文; 欧阳伟; 王国忠. 35kV变电站的雷电侵入波的仿真分析[J]. 南昌大学学报(工科版), 2009, 31(04): 1-.