XIE Guang-feng1,LI Huo-kun2 (1.Water Conservancy and Electric Power Reconnaissance Designing institute of Jiangxi Shangrao,Shangrao,334000,China;2.School of Civil Engineering,Nanchang University,Nanchang 330031,China)
Abstract:Taking the high-head and great HD magnitude lapel type bifurcated pipe with cresent rib of a hydroelectric station as an example,this paper calculates the bifurcated pipe structrue stress using 3-D FEM,analyzes the stress state of this bifurcated pipe.The